Technical Report WRD92039 Viewed at 15:07:17 on 29/07/2010 Page 134 of 192. lil;CTIQN 10. SERIES 300013500 PATA LOGGER SPEOFICATIONS ELECTRICAL: Processor. 80C652 Operating Temperature. - 10C to + 60C. Clock: Type Crystal regulated, Real Time. 10 seconds per month. EPROM or EEPROM. Accuracy Memory: Type Log interval. Inputs Cc,nfiguration: Input Spe<:ification: Communkation: Power: l\'fECHANICAL: Enclosur,~: Connectors: Capacity Model 3000 Model35D0 Analogue (Non-volatile 10 year data retention) 128K standard. 1 second to 24 hours. 2 X Analogue 1 X Switch Closure 4XAnalogue 1 X Switch Closure 1 X Rotary Encoder ( Model AD375 ) Accuracy & Resolution 1:20,000 ( approx 14.5 bit) Nominal 12VDC switch power supplied to se.'lSors. switch on 1 second standard, total 500mA all inputs Switch closure Normally open. Encoder Imm increments, maximum rate 10 metres I minute RS232 1200 I 9600 Baud 8 data bits, 1 stop bit, parity ignore. 2 X internal sealed lead add batteries, 12V 2.2A, each. Average recharge or exchange requirement - 4 months. Material Protection Material Protection Tough impact resistant ABS IP67, submersible. Plated brass, gold plated contacts. Submersible rated to 30 metres water. Mountin:,. Weight: Shelf or wall mount using screws through base outside of gaskcted area. 1250 gms excluding batteries 2890 gms including batteries Dimensi'Jns. 230 X 140 X 95 mm 1 7