Technical Report WRD92039 Viewed at 15:07:17 on 29/07/2010 Page 160 of 192. C2.4.2 Loggers which cannot have recalibration parameters entered directly (e.g. Mindata) since the original calibration can only be changed through the calibration routine (allowing only a 2 point calibration) the logger can't have fine adjustments made to its' calibration. Thus the 8 and 0 values must be used at the data editing stage, by RC = LD " s + 0 where RC is the recalibrated data, LD is the logged data (using the original 2 point calibration) and sand 0 are as calculated (including sign) in section C2.3.1 above. 'Ihis recalibration should be done before any further data manipulation, e.g. barometric correction or comparison to manual readings are done. . .