Gapuwiyak borefield, bore construction report. Dlh-500
Prowse, G.
E-Publications; ebooks; PublicationNT; E-Books; 04/83D
1983
Made available via the Publications (Legal Deposit) Act 2004 (NT).
Date:1983
English
04/83D
application/pdf.
Check within Publication or with content Publisher.
https://hdl.handle.net/10070/228656
https://hdl.handle.net/10070/673872
Technical Report WRD83004 Viewed at 14:07:13 on 29/07/2010 Page 14 of 24. I I I I I I I I I I I I I I I I I I I I 9. RECOMMENDATIONS It is recommended that: (i) New bore RN 21403 should be equipped with a pump capable of pumping 8 Lis at a pump inlet setting of 21.9 m below ground level; (ii) Existing production bore RN 8900 should be equipped with a pump capable of pumping 8 Lis at a setting of 23 m and used as a standby bore; (iii) The pumping from the lake should be discontinued; (iv) Water levels should be monitored from the observation bores, on a six weekly basis; (v) Further work is required to investigate the areal extent of the groundwater source.
Aboriginal and Torres Strait Islander people are advised that this website may contain the names, voices and images of people who have died, as well as other culturally sensitive content. Please be aware that some collection items may use outdated phrases or words which reflect the attitude of the creator at the time, and are now considered offensive.